Filters
Question type

Describe Type d equipment.

Correct Answer

verifed

verified

Type d equipment is permitted ...

View Answer

As a result of major changes to the 2011 Code, equipment marking designations for protection may be a prefix or suffix letter to indicate D for dust, G for gas, and M for mining.

A) True
B) False

Correct Answer

verifed

verified

What are the steps in wiring a hazardous location?

Correct Answer

verifed

verified

The first step for wiring in a hazardous...

View Answer

One of the major changes to the 2011 Code is that a new definition was added for ____________________ dust.

Correct Answer

verifed

verified

What happens to ignition gases during an internal explosion?

Correct Answer

verifed

verified

The high pressure developed du...

View Answer

An area is considered hazardous because of the highly flammable nature of a vapor, gas, dust, or solid material that may be easily ignited to cause fire or an explosion.

A) True
B) False

Correct Answer

verifed

verified

Class I is separated into which three zones?

Correct Answer

verifed

verified

Zone 0, Zo...

View Answer

What is the meaning of 'Zone2/1'?

Correct Answer

verifed

verified

'Zone2/1' implies that a devic...

View Answer

Class I locations are characterized by flammable flyings and fibers.

A) True
B) False

Correct Answer

verifed

verified

False

Class ____________________ is characterized by flammable dust.

Correct Answer

verifed

verified

The division line between hazardous and non-hazardous may be a physical barrier, or it may simply be a distance limit.

A) True
B) False

Correct Answer

verifed

verified

An example of an enclosure marking may be Zone 1, AEx, d, IIA, T4, Gb.What is the meaning of 'Gb,?

Correct Answer

verifed

verified

'G' stands for gas, ...

View Answer

Extra care must be taken to make sure the grounding path in a hazardous location is of ____________________ impedance.

Correct Answer

verifed

verified

Describe type n equipment, and list its three subcategories.

Correct Answer

verifed

verified

Equipment that is provided with type n p...

View Answer

A Division 1 area is one in which, under normal operating conditions, a hazardous material is present in dangerous quantities only because of accidental spills or other unusual circumstances.

A) True
B) False

Correct Answer

verifed

verified

Equipment type ____________________ is purged and pressurized.

Correct Answer

verifed

verified

Type ___________________ equipment is known as increased safety equipment.

Correct Answer

verifed

verified

e

Type ____________________ is intrinsically safe equipment intended for use in Zone 0.

Correct Answer

verifed

verified

Flameproof protection is identified by the letter ____________________.

Correct Answer

verifed

verified

d

A Division ___________________ area is one in which the hazardous material is likely to be present.

Correct Answer

verifed

verified

Showing 1 - 20 of 20